Fire and Life Safety Division
Installation of water based fire fighting systems, including pumps, sprinklers, hydrants, hose reels, risers and associated distribution networks.
Specialist service
A coordinated installation makes the relationship between water supply, distribution and system operation clearer during testing, handover and subsequent maintenance.
The requirement
Water based fire protection depends on the coordinated performance of pumps, pipework, storage, valves and discharge devices. EXA TECK’s installation scope covers these components as a connected system rather than separate items. We coordinate equipment positions, distribution routes and access for inspection against the approved fire protection design. The package includes defined installation checks and preparation for the specified system testing and handover activities.
The service in detail
A water based firefighting system connects the water supply to the equipment that delivers it where required. Pumps, storage, distribution pipework, sprinklers, hydrants and hose reels therefore need to be considered together. The building use and approved design determine the installation requirements, while equipment access and clear identification support later operation and maintenance.
The agreed scope begins with reviewing the drawings, equipment schedule, routes and connections. Supports, valves and pipework are coordinated with structural and architectural work before ceilings or service spaces are closed. Pump rooms and storage interfaces require attention to access, controls and the specified connections. Extensions to an existing network also need an agreed plan for isolation and reinstatement, with the impact on the occupied building reviewed in advance.
Inspection and testing follow the project requirements and the agreed commissioning scope, including relevant pipework and pump checks. Results, identified defects and retesting requirements should be clear before handover. Equipment references, valve identification and available system drawings help the building team manage the installation. Send EXA TECK the project location, building use, approved layout and the systems required so the firefighting installation package can be assessed.
Start the conversation
Share your approved fire fighting drawings to discuss the installation package.
Scope of services
Select the work packages relevant to your property. The final scope is agreed around the site and technical requirements.
01
Installation of specified fire pump sets and controllers, coordinating foundations, connections, power interfaces and service access with the approved pump room arrangement.
02
Installation of sprinkler pipework and specified sprinkler heads, coordinating coverage requirements, ceiling interfaces, obstructions and access to associated control and inspection points.
03
Installation of hydrants, hose reels and their connections, with positions and access coordinated to the approved design and the layout of the protected area.
04
Installation of specified wet or dry risers, including landing valves, inlets and associated pipework, coordinated with building layouts and the approved system arrangement.
05
Installation of distribution pipework, supports, isolation and control valves, with identification, accessibility and interfaces to other trades considered throughout the routing process.
06
Installation of specified fire water storage and distribution connections, coordinating capacity requirements established by the design with pump suction arrangements and access provisions.
Let’s talk
Share your approved fire fighting drawings to discuss the installation package.
Related services
01
Installation of fire alarm panels, detectors and warning devices, with coordinated system interfaces and documented functional verification.
02
Specialist suppression installation packages for defined hazards, including clean agent, CO2, foam and commercial kitchen protection systems.
03
Emergency lighting, exit signs and evacuation communication installations coordinated with the building layout and approved emergency strategy.
Questions, answered
The scope can include Fire Pump Sets and Controllers, Automatic Fire Sprinkler Systems, Fire Hydrants and Hose Reels, Wet and Dry Riser Systems, Fire Fighting Pipework and Valves, Fire Water Storage and Distribution. The relevant work packages, quantities and exclusions are defined around your property and confirmed in the proposal.
Provide the building use, available drawings and details of pumps, water storage, sprinklers, hydrants or hose reels. Describe whether you need new installation, modifications or an assessment of existing equipment.
Share your property location, building use, the work required and preferred timing. Available drawings, photographs, equipment details or previous reports can help us assess your fire fighting systems requirements.
The quotation and programme depend on the scope, quantities, materials or equipment, site access and any required coordination. Further technical details or a site visit may be needed before these can be confirmed.
Use the enquiry form below, call +971 58 585 8415 or message the same number on WhatsApp. You can also email [email protected] with your project details.
Share your requirements for fire fighting systems. Include the property location and preferred timing so we can discuss the next step.
Prefer to talk? +971 58 585 8415 · [email protected]
Share the location, property type, service required, and the result you need.
Building insights
Practical guidance for project briefs, maintenance proposals and useful handover records.
EXA TECK supports construction, fire safety and ongoing property care across the UAE. Explore four coordinated divisions and a clearly defined scope for your building.
© 2026 EXA TECK. All rights reserved.